Loading report..

Highlight Samples

Regex mode off

    Rename Samples

    Click here for bulk input.

    Paste two columns of a tab-delimited table here (eg. from Excel).

    First column should be the old name, second column the new name.

    Regex mode off

      Show / Hide Samples

      Regex mode off

        Export Plots

        px
        px
        X

        Download the raw data used to create the plots in this report below:

        Note that additional data was saved in multiqc_data when this report was generated.


        Choose Plots

        If you use plots from MultiQC in a publication or presentation, please cite:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        Save Settings

        You can save the toolbox settings for this report to the browser.


        Load Settings

        Choose a saved report profile from the dropdown box below:

        About MultiQC

        This report was generated using MultiQC, version 1.9

        You can see a YouTube video describing how to use MultiQC reports here: https://youtu.be/qPbIlO_KWN0

        For more information about MultiQC, including other videos and extensive documentation, please visit http://multiqc.info

        You can report bugs, suggest improvements and find the source code for MultiQC on GitHub: https://github.com/ewels/MultiQC

        MultiQC is published in Bioinformatics:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        A modular tool to aggregate results from bioinformatics analyses across many samples into a single report.

        Report generated on 2021-02-27, 03:32 based on data in: /scratch/gencore/logs/html/HLN27AFX2/merged


        General Statistics

        Showing 46/46 rows and 3/5 columns.
        Sample Name% Dups% GCM Seqs
        HLN27AFX2_n01_AH10355_4h_rep1
        46.0%
        42%
        3.7
        HLN27AFX2_n01_AH10355_4h_rep2
        45.1%
        42%
        3.4
        HLN27AFX2_n01_AH10355_4h_rep3
        54.1%
        42%
        7.1
        HLN27AFX2_n01_AH10423_4h_rep1
        42.9%
        42%
        2.9
        HLN27AFX2_n01_AH10423_4h_rep2
        49.8%
        43%
        3.3
        HLN27AFX2_n01_AH10423_4h_rep3
        57.1%
        43%
        9.8
        HLN27AFX2_n01_AH10517-3h-antiRED1
        41.3%
        42%
        9.5
        HLN27AFX2_n01_AH10517-3h-input
        24.3%
        39%
        8.0
        HLN27AFX2_n01_AH10819_4h_rep1
        44.5%
        42%
        3.5
        HLN27AFX2_n01_AH10819_4h_rep2
        39.3%
        42%
        2.3
        HLN27AFX2_n01_AH10819_4h_rep3
        58.0%
        42%
        7.7
        HLN27AFX2_n01_AH10820_4h_rep1
        54.3%
        42%
        7.4
        HLN27AFX2_n01_AH10820_4h_rep2
        53.5%
        43%
        5.3
        HLN27AFX2_n01_AH10820_4h_rep3
        61.1%
        43%
        8.6
        HLN27AFX2_n01_AH10961-3h-antiRED1
        59.6%
        46%
        13.7
        HLN27AFX2_n01_AH10961-3h-input
        35.7%
        39%
        15.6
        HLN27AFX2_n01_AH10962-3h-antiRED1
        53.4%
        44%
        10.1
        HLN27AFX2_n01_AH10962-3h-input
        31.5%
        39%
        12.2
        HLN27AFX2_n01_AH10965-3h-antiRED1
        33.9%
        41%
        7.9
        HLN27AFX2_n01_AH10965-3h-input
        31.9%
        39%
        12.5
        HLN27AFX2_n01_AH9866-3h-antiRED1
        45.8%
        43%
        9.9
        HLN27AFX2_n01_AH9866-3h-input
        30.1%
        39%
        10.4
        HLN27AFX2_n01_undetermined
        40.7%
        42%
        4.2
        HLN27AFX2_n02_AH10355_4h_rep1
        52.0%
        41%
        3.7
        HLN27AFX2_n02_AH10355_4h_rep2
        50.6%
        42%
        3.4
        HLN27AFX2_n02_AH10355_4h_rep3
        57.3%
        42%
        7.1
        HLN27AFX2_n02_AH10423_4h_rep1
        49.2%
        42%
        2.9
        HLN27AFX2_n02_AH10423_4h_rep2
        53.0%
        43%
        3.3
        HLN27AFX2_n02_AH10423_4h_rep3
        60.2%
        43%
        9.8
        HLN27AFX2_n02_AH10517-3h-antiRED1
        38.8%
        43%
        9.5
        HLN27AFX2_n02_AH10517-3h-input
        23.1%
        39%
        8.0
        HLN27AFX2_n02_AH10819_4h_rep1
        51.5%
        41%
        3.5
        HLN27AFX2_n02_AH10819_4h_rep2
        46.8%
        42%
        2.3
        HLN27AFX2_n02_AH10819_4h_rep3
        61.6%
        42%
        7.7
        HLN27AFX2_n02_AH10820_4h_rep1
        62.0%
        41%
        7.4
        HLN27AFX2_n02_AH10820_4h_rep2
        53.6%
        46%
        5.3
        HLN27AFX2_n02_AH10820_4h_rep3
        60.4%
        46%
        8.6
        HLN27AFX2_n02_AH10961-3h-antiRED1
        56.3%
        46%
        13.7
        HLN27AFX2_n02_AH10961-3h-input
        33.8%
        39%
        15.6
        HLN27AFX2_n02_AH10962-3h-antiRED1
        50.6%
        45%
        10.1
        HLN27AFX2_n02_AH10962-3h-input
        29.8%
        39%
        12.2
        HLN27AFX2_n02_AH10965-3h-antiRED1
        31.9%
        42%
        7.9
        HLN27AFX2_n02_AH10965-3h-input
        26.7%
        40%
        12.5
        HLN27AFX2_n02_AH9866-3h-antiRED1
        43.4%
        43%
        9.9
        HLN27AFX2_n02_AH9866-3h-input
        28.5%
        39%
        10.4
        HLN27AFX2_n02_undetermined
        41.8%
        46%
        4.2

        Barcodes of Undetermined Reads


        We have determined the barcodes of your undetermined reads (reads containing a barcode that you did not encode in your metadata). Here are the top 20 barcodes belonging to the undetermined reads. The full list is available here.

        Showing 20/20 rows and 2/2 columns.
        Barcode Sequence(s)CountFrequency (%)
        GGGGGG
        2739018.0
        65.4
        NNNNNN
        77888.0
        1.9
        GTTCGG
        23151.0
        0.6
        GGGGGC
        15312.0
        0.4
        GTGGGG
        13345.0
        0.3
        CAGTCA
        12889.0
        0.3
        ACTGAA
        12218.0
        0.3
        GGGGCG
        11645.0
        0.3
        ACCAGT
        11173.0
        0.3
        CCGATG
        10509.0
        0.2
        CGATCA
        10132.0
        0.2
        GTCCCG
        9547.0
        0.2
        CGTTTC
        9487.0
        0.2
        GGCGGG
        8904.0
        0.2
        CGGCTA
        8867.0
        0.2
        GGGGGT
        8802.0
        0.2
        GCGGGG
        8730.0
        0.2
        GATGTA
        8394.0
        0.2
        GATCCA
        8079.0
        0.2
        GTCAAC
        7881.0
        0.2

        Demultiplexing Report


        Total Read Count: Total number of PF (Passing Filter) reads in this library.
        Portion: The proportion of reads that represent the individual library in the entire Library Pool.

        Showing 23/23 rows and 2/2 columns.
        LibraryTotal Read CountPortion (%)
        undetermined_library
        4187667
        2.3
        AH10517-3h-antiRED1
        9516020
        5.3
        AH10517-3h-input
        8039066
        4.5
        AH9866-3h-antiRED1
        9917437
        5.5
        AH9866-3h-input
        10449757
        5.8
        AH10965-3h-antiRED1
        7945601
        4.4
        AH10965-3h-input
        12493219
        7.0
        AH10961-3h-antiRED1
        13677807
        7.6
        AH10961-3h-input
        15643677
        8.7
        AH10962-3h-antiRED1
        10097841
        5.6
        AH10962-3h-input
        12162331
        6.8
        AH10355_4h_rep1
        3667090
        2.0
        AH10423_4h_rep1
        2909358
        1.6
        AH10819_4h_rep1
        3542446
        2.0
        AH10820_4h_rep1
        7404160
        4.1
        AH10355_4h_rep2
        3418914
        1.9
        AH10423_4h_rep2
        3311278
        1.8
        AH10819_4h_rep2
        2321059
        1.3
        AH10820_4h_rep2
        5329178
        3.0
        AH10819_4h_rep3
        7658383
        4.3
        AH10355_4h_rep3
        7105803
        4.0
        AH10423_4h_rep3
        9814739
        5.5
        AH10820_4h_rep3
        8622728
        4.8

        Run Statistics

        Showing 1/1 rows and 4/4 columns.
        Number of LanesTotal # of Single-End ReadsTotal # PF Reads% Undetermined% PhiX Aligned
        4.0
        199068676
        179235559
        2.3
        0.6

        FastQC

        FastQC is a quality control tool for high throughput sequence data, written by Simon Andrews at the Babraham Institute in Cambridge.

        Sequence Counts

        Sequence counts for each sample. Duplicate read counts are an estimate only.

        This plot show the total number of reads, broken down into unique and duplicate if possible (only more recent versions of FastQC give duplicate info).

        You can read more about duplicate calculation in the FastQC documentation. A small part has been copied here for convenience:

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        loading..

        Sequence Quality Histograms

        The mean quality value across each base position in the read.

        To enable multiple samples to be plotted on the same graph, only the mean quality scores are plotted (unlike the box plots seen in FastQC reports).

        Taken from the FastQC help:

        The y-axis on the graph shows the quality scores. The higher the score, the better the base call. The background of the graph divides the y axis into very good quality calls (green), calls of reasonable quality (orange), and calls of poor quality (red). The quality of calls on most platforms will degrade as the run progresses, so it is common to see base calls falling into the orange area towards the end of a read.

        loading..

        Per Sequence Quality Scores

        The number of reads with average quality scores. Shows if a subset of reads has poor quality.

        From the FastQC help:

        The per sequence quality score report allows you to see if a subset of your sequences have universally low quality values. It is often the case that a subset of sequences will have universally poor quality, however these should represent only a small percentage of the total sequences.

        loading..

        Per Base Sequence Content

        The proportion of each base position for which each of the four normal DNA bases has been called.

        To enable multiple samples to be shown in a single plot, the base composition data is shown as a heatmap. The colours represent the balance between the four bases: an even distribution should give an even muddy brown colour. Hover over the plot to see the percentage of the four bases under the cursor.

        To see the data as a line plot, as in the original FastQC graph, click on a sample track.

        From the FastQC help:

        Per Base Sequence Content plots out the proportion of each base position in a file for which each of the four normal DNA bases has been called.

        In a random library you would expect that there would be little to no difference between the different bases of a sequence run, so the lines in this plot should run parallel with each other. The relative amount of each base should reflect the overall amount of these bases in your genome, but in any case they should not be hugely imbalanced from each other.

        It's worth noting that some types of library will always produce biased sequence composition, normally at the start of the read. Libraries produced by priming using random hexamers (including nearly all RNA-Seq libraries) and those which were fragmented using transposases inherit an intrinsic bias in the positions at which reads start. This bias does not concern an absolute sequence, but instead provides enrichement of a number of different K-mers at the 5' end of the reads. Whilst this is a true technical bias, it isn't something which can be corrected by trimming and in most cases doesn't seem to adversely affect the downstream analysis.

        Click a sample row to see a line plot for that dataset.
        Rollover for sample name
        Position: -
        %T: -
        %C: -
        %A: -
        %G: -

        Per Sequence GC Content

        The average GC content of reads. Normal random library typically have a roughly normal distribution of GC content.

        From the FastQC help:

        This module measures the GC content across the whole length of each sequence in a file and compares it to a modelled normal distribution of GC content.

        In a normal random library you would expect to see a roughly normal distribution of GC content where the central peak corresponds to the overall GC content of the underlying genome. Since we don't know the the GC content of the genome the modal GC content is calculated from the observed data and used to build a reference distribution.

        An unusually shaped distribution could indicate a contaminated library or some other kinds of biased subset. A normal distribution which is shifted indicates some systematic bias which is independent of base position. If there is a systematic bias which creates a shifted normal distribution then this won't be flagged as an error by the module since it doesn't know what your genome's GC content should be.

        loading..

        Per Base N Content

        The percentage of base calls at each position for which an N was called.

        From the FastQC help:

        If a sequencer is unable to make a base call with sufficient confidence then it will normally substitute an N rather than a conventional base call. This graph shows the percentage of base calls at each position for which an N was called.

        It's not unusual to see a very low proportion of Ns appearing in a sequence, especially nearer the end of a sequence. However, if this proportion rises above a few percent it suggests that the analysis pipeline was unable to interpret the data well enough to make valid base calls.

        loading..

        Sequence Length Distribution

        All samples have sequences of a single length (76bp).

        Sequence Duplication Levels

        The relative level of duplication found for every sequence.

        From the FastQC Help:

        In a diverse library most sequences will occur only once in the final set. A low level of duplication may indicate a very high level of coverage of the target sequence, but a high level of duplication is more likely to indicate some kind of enrichment bias (eg PCR over amplification). This graph shows the degree of duplication for every sequence in a library: the relative number of sequences with different degrees of duplication.

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        In a properly diverse library most sequences should fall into the far left of the plot in both the red and blue lines. A general level of enrichment, indicating broad oversequencing in the library will tend to flatten the lines, lowering the low end and generally raising other categories. More specific enrichments of subsets, or the presence of low complexity contaminants will tend to produce spikes towards the right of the plot.

        loading..

        Overrepresented sequences

        The total amount of overrepresented sequences found in each library.

        FastQC calculates and lists overrepresented sequences in FastQ files. It would not be possible to show this for all samples in a MultiQC report, so instead this plot shows the number of sequences categorized as over represented.

        Sometimes, a single sequence may account for a large number of reads in a dataset. To show this, the bars are split into two: the first shows the overrepresented reads that come from the single most common sequence. The second shows the total count from all remaining overrepresented sequences.

        From the FastQC Help:

        A normal high-throughput library will contain a diverse set of sequences, with no individual sequence making up a tiny fraction of the whole. Finding that a single sequence is very overrepresented in the set either means that it is highly biologically significant, or indicates that the library is contaminated, or not as diverse as you expected.

        FastQC lists all of the sequences which make up more than 0.1% of the total. To conserve memory only sequences which appear in the first 100,000 sequences are tracked to the end of the file. It is therefore possible that a sequence which is overrepresented but doesn't appear at the start of the file for some reason could be missed by this module.

        loading..

        Adapter Content

        The cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position.

        Note that only samples with ≥ 0.1% adapter contamination are shown.

        There may be several lines per sample, as one is shown for each adapter detected in the file.

        From the FastQC Help:

        The plot shows a cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position. Once a sequence has been seen in a read it is counted as being present right through to the end of the read so the percentages you see will only increase as the read length goes on.

        loading..

        Status Checks

        Status for each FastQC section showing whether results seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        FastQC assigns a status for each section of the report. These give a quick evaluation of whether the results of the analysis seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        It is important to stress that although the analysis results appear to give a pass/fail result, these evaluations must be taken in the context of what you expect from your library. A 'normal' sample as far as FastQC is concerned is random and diverse. Some experiments may be expected to produce libraries which are biased in particular ways. You should treat the summary evaluations therefore as pointers to where you should concentrate your attention and understand why your library may not look random and diverse.

        Specific guidance on how to interpret the output of each module can be found in the relevant report section, or in the FastQC help.

        In this heatmap, we summarise all of these into a single heatmap for a quick overview. Note that not all FastQC sections have plots in MultiQC reports, but all status checks are shown in this heatmap.

        loading..