Highlight Samples

Regex mode off

    Rename Samples

    Click here for bulk input.

    Paste two columns of a tab-delimited table here (eg. from Excel).

    First column should be the old name, second column the new name.

    Regex mode off

      Show / Hide Samples

      Regex mode off

        Export Plots

        px
        px
        X

        Download the raw data used to create the plots in this report below:

        Note that additional data was saved in multiqc_data when this report was generated.


        Choose Plots

        If you use plots from MultiQC in a publication or presentation, please cite:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        Save Settings

        You can save the toolbox settings for this report to the browser.


        Load Settings

        Choose a saved report profile from the dropdown box below:

        About MultiQC

        This report was generated using MultiQC, version 1.9

        You can see a YouTube video describing how to use MultiQC reports here: https://youtu.be/qPbIlO_KWN0

        For more information about MultiQC, including other videos and extensive documentation, please visit http://multiqc.info

        You can report bugs, suggest improvements and find the source code for MultiQC on GitHub: https://github.com/ewels/MultiQC

        MultiQC is published in Bioinformatics:

        MultiQC: Summarize analysis results for multiple tools and samples in a single report
        Philip Ewels, Måns Magnusson, Sverker Lundin and Max Käller
        Bioinformatics (2016)
        doi: 10.1093/bioinformatics/btw354
        PMID: 27312411

        A modular tool to aggregate results from bioinformatics analyses across many samples into a single report.

        Report generated on 2021-12-15, 16:48 based on data in: /scratch/gencore/logs/html/H5MVLDMXY/merged

        Welcome! Not sure where to start?   Watch a tutorial video   (6:06)

        General Statistics

        Showing 34/34 rows and 3/5 columns.
        Sample Name% Dups% GCM Seqs
        H5MVLDMXY_n01_BG0061
        20.7%
        41%
        290.0
        H5MVLDMXY_n01_BG0062
        20.9%
        39%
        218.8
        H5MVLDMXY_n01_BG0063
        27.1%
        42%
        299.8
        H5MVLDMXY_n01_BG0067
        19.6%
        41%
        263.9
        H5MVLDMXY_n01_NR0057
        17.1%
        42%
        234.7
        H5MVLDMXY_n01_NR0057.1
        19.2%
        41%
        245.4
        H5MVLDMXY_n01_NR0154
        35.1%
        44%
        183.5
        H5MVLDMXY_n01_NR0154.1
        83.8%
        20%
        285.4
        H5MVLDMXY_n01_Pf3D7
        39.9%
        33%
        237.8
        H5MVLDMXY_n01_RN0068
        21.5%
        41%
        295.0
        H5MVLDMXY_n01_RN0069
        19.0%
        41%
        238.6
        H5MVLDMXY_n01_RN0072
        65.5%
        24%
        252.3
        H5MVLDMXY_n01_mook198_2
        49.5%
        48%
        222.9
        H5MVLDMXY_n01_sidu001_4
        29.2%
        47%
        217.0
        H5MVLDMXY_n01_sidu032_3
        66.1%
        60%
        267.5
        H5MVLDMXY_n01_sidu036_1
        83.8%
        59%
        312.5
        H5MVLDMXY_n01_undetermined
        33.1%
        39%
        123.1
        H5MVLDMXY_n02_BG0061
        19.2%
        41%
        290.0
        H5MVLDMXY_n02_BG0062
        20.3%
        39%
        218.8
        H5MVLDMXY_n02_BG0063
        26.6%
        42%
        299.8
        H5MVLDMXY_n02_BG0067
        19.1%
        41%
        263.9
        H5MVLDMXY_n02_NR0057
        17.8%
        42%
        234.7
        H5MVLDMXY_n02_NR0057.1
        18.7%
        41%
        245.4
        H5MVLDMXY_n02_NR0154
        34.0%
        44%
        183.5
        H5MVLDMXY_n02_NR0154.1
        83.6%
        20%
        285.4
        H5MVLDMXY_n02_Pf3D7
        40.5%
        33%
        237.8
        H5MVLDMXY_n02_RN0068
        21.2%
        41%
        295.0
        H5MVLDMXY_n02_RN0069
        18.5%
        41%
        238.6
        H5MVLDMXY_n02_RN0072
        66.4%
        24%
        252.3
        H5MVLDMXY_n02_mook198_2
        50.5%
        48%
        222.9
        H5MVLDMXY_n02_sidu001_4
        28.1%
        47%
        217.0
        H5MVLDMXY_n02_sidu032_3
        65.2%
        60%
        267.5
        H5MVLDMXY_n02_sidu036_1
        81.0%
        59%
        312.5
        H5MVLDMXY_n02_undetermined
        32.6%
        40%
        123.1

        Barcodes of Undetermined Reads


        We have determined the barcodes of your undetermined reads (reads containing a barcode that you did not encode in your metadata). Here are the top 20 barcodes belonging to the undetermined reads. The full list is available here.

        Showing 20/20 rows and 2/2 columns.
        Barcode Sequence(s)CountFrequency (%)
        GGGGGGGGGGAGATCTCGGT
        30666211.0
        24.9
        GGGGGGGGGGTGATCTCGGT
        705328.0
        0.6
        GGGGGGGGGGAGGACAGGCC
        622123.0
        0.5
        CACCAGGCAAATTCCATAAG
        456740.0
        0.4
        CCACCGGCAAATTCCATAAG
        455208.0
        0.4
        TATGCGCTCACCTAACACAG
        437385.0
        0.4
        GGGGGGGGGGTTACAGTTAG
        405554.0
        0.3
        TGATTATACGGGGGGGGGGG
        389927.0
        0.3
        AAAAAAAAAAAAAAAAAAAA
        353527.0
        0.3
        GGGGGGGGGGCGAGGTCGGA
        328475.0
        0.3
        GGGGGGGGGGTGTAATCGAC
        303310.0
        0.2
        GGGGGGGGGGCGATCTCGGT
        293356.0
        0.2
        GGGGGGGGGGCACGGCTAGT
        274837.0
        0.2
        GGGGGGGGGGCCGTATGTTC
        271357.0
        0.2
        GGGGGGGGGGTTGCTCTATT
        261349.0
        0.2
        TCTACATACATTACAGTTAG
        257091.0
        0.2
        CCACAGGCAAATTCCATAAG
        256585.0
        0.2
        TTCTACATACGGGGGGGGGG
        227349.0
        0.2
        GGGGGGGGGGACGTTCCTTA
        223312.0
        0.2
        TTCACATACATTACAGTTAG
        212280.0
        0.2

        Demultiplexing Report


        Total Read Count: Total number of PF (Passing Filter) reads in this library.
        Portion: The proportion of reads that represent the individual library in the entire Library Pool.

        Showing 17/17 rows and 2/2 columns.
        LibraryTotal Read CountPortion (%)
        undetermined_library
        123103579
        2.9
        Pf3D7
        237757486
        5.7
        NR0057
        234727700
        5.6
        NR0154
        183546207
        4.4
        NR0057.1
        245442058
        5.9
        NR0154.1
        285434368
        6.8
        RN0068
        295003840
        7.0
        RN0069
        238585647
        5.7
        BG0061
        290027058
        6.9
        BG0062
        218822248
        5.2
        BG0063
        299787396
        7.2
        RN0072
        252337062
        6.0
        BG0067
        263929001
        6.3
        mook198_2
        222928405
        5.3
        sidu001_4
        217045923
        5.2
        sidu032_3
        267502705
        6.4
        sidu036_1
        312541365
        7.5

        Run Statistics

        Showing 1/1 rows and 4/4 columns.
        Number of LanesTotal # of Single-End ReadsTotal # PF Reads% Undetermined% PhiX Aligned
        2.0
        5761400832
        4188522048
        2.9
        0.8

        FastQC

        FastQC is a quality control tool for high throughput sequence data, written by Simon Andrews at the Babraham Institute in Cambridge.

        Sequence Counts

        Sequence counts for each sample. Duplicate read counts are an estimate only.

        This plot show the total number of reads, broken down into unique and duplicate if possible (only more recent versions of FastQC give duplicate info).

        You can read more about duplicate calculation in the FastQC documentation. A small part has been copied here for convenience:

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        Created with Highcharts 5.0.6Number of readsChart context menuExport PlotFastQC: Sequence CountsUnique ReadsDuplicate ReadsH5MVLDMXY_n01_BG0061H5MVLDMXY_n01_BG0063H5MVLDMXY_n01_NR0057H5MVLDMXY_n01_NR0154H5MVLDMXY_n01_Pf3D7H5MVLDMXY_n01_RN0069H5MVLDMXY_n01_mook198_2H5MVLDMXY_n01_sidu032_3H5MVLDMXY_n01_undeterminedH5MVLDMXY_n02_BG0062H5MVLDMXY_n02_BG0067H5MVLDMXY_n02_NR0057.1H5MVLDMXY_n02_NR0154.1H5MVLDMXY_n02_RN0068H5MVLDMXY_n02_RN0072H5MVLDMXY_n02_sidu001_4H5MVLDMXY_n02_sidu036_1025M50M75M100M125M150M175M200M225M250M275M300M325M35…350MCreated with MultiQC

        Sequence Quality Histograms
        34
        0
        0

        The mean quality value across each base position in the read.

        To enable multiple samples to be plotted on the same graph, only the mean quality scores are plotted (unlike the box plots seen in FastQC reports).

        Taken from the FastQC help:

        The y-axis on the graph shows the quality scores. The higher the score, the better the base call. The background of the graph divides the y axis into very good quality calls (green), calls of reasonable quality (orange), and calls of poor quality (red). The quality of calls on most platforms will degrade as the run progresses, so it is common to see base calls falling into the orange area towards the end of a read.

        Created with Highcharts 5.0.6Position (bp)Phred ScoreChart context menuExport PlotFastQC: Mean Quality Scores1020304050607080901000510152025303540Created with MultiQC

        Per Sequence Quality Scores
        34
        0
        0

        The number of reads with average quality scores. Shows if a subset of reads has poor quality.

        From the FastQC help:

        The per sequence quality score report allows you to see if a subset of your sequences have universally low quality values. It is often the case that a subset of sequences will have universally poor quality, however these should represent only a small percentage of the total sequences.

        Created with Highcharts 5.0.6Mean Sequence Quality (Phred Score)CountChart context menuExport PlotFastQC: Per Sequence Quality Scores051015202530350250000005000000075000000100000000125000000150000000175000000200000000Created with MultiQC

        Per Base Sequence Content
        0
        0
        34

        The proportion of each base position for which each of the four normal DNA bases has been called.

        To enable multiple samples to be shown in a single plot, the base composition data is shown as a heatmap. The colours represent the balance between the four bases: an even distribution should give an even muddy brown colour. Hover over the plot to see the percentage of the four bases under the cursor.

        To see the data as a line plot, as in the original FastQC graph, click on a sample track.

        From the FastQC help:

        Per Base Sequence Content plots out the proportion of each base position in a file for which each of the four normal DNA bases has been called.

        In a random library you would expect that there would be little to no difference between the different bases of a sequence run, so the lines in this plot should run parallel with each other. The relative amount of each base should reflect the overall amount of these bases in your genome, but in any case they should not be hugely imbalanced from each other.

        It's worth noting that some types of library will always produce biased sequence composition, normally at the start of the read. Libraries produced by priming using random hexamers (including nearly all RNA-Seq libraries) and those which were fragmented using transposases inherit an intrinsic bias in the positions at which reads start. This bias does not concern an absolute sequence, but instead provides enrichement of a number of different K-mers at the 5' end of the reads. Whilst this is a true technical bias, it isn't something which can be corrected by trimming and in most cases doesn't seem to adversely affect the downstream analysis.

        Click a sample row to see a line plot for that dataset.
        Rollover for sample name
        Position: -
        %T: -
        %C: -
        %A: -
        %G: -

        Per Sequence GC Content
        4
        20
        10

        The average GC content of reads. Normal random library typically have a roughly normal distribution of GC content.

        From the FastQC help:

        This module measures the GC content across the whole length of each sequence in a file and compares it to a modelled normal distribution of GC content.

        In a normal random library you would expect to see a roughly normal distribution of GC content where the central peak corresponds to the overall GC content of the underlying genome. Since we don't know the the GC content of the genome the modal GC content is calculated from the observed data and used to build a reference distribution.

        An unusually shaped distribution could indicate a contaminated library or some other kinds of biased subset. A normal distribution which is shifted indicates some systematic bias which is independent of base position. If there is a systematic bias which creates a shifted normal distribution then this won't be flagged as an error by the module since it doesn't know what your genome's GC content should be.

        Created with Highcharts 5.0.6% GCPercentageChart context menuExport PlotFastQC: Per Sequence GC Content01020304050607080901000123456Created with MultiQC

        Per Base N Content
        34
        0
        0

        The percentage of base calls at each position for which an N was called.

        From the FastQC help:

        If a sequencer is unable to make a base call with sufficient confidence then it will normally substitute an N rather than a conventional base call. This graph shows the percentage of base calls at each position for which an N was called.

        It's not unusual to see a very low proportion of Ns appearing in a sequence, especially nearer the end of a sequence. However, if this proportion rises above a few percent it suggests that the analysis pipeline was unable to interpret the data well enough to make valid base calls.

        Created with Highcharts 5.0.6Position in Read (bp)Percentage N-CountChart context menuExport PlotFastQC: Per Base N Content01020304050607080901000123456Created with MultiQC

        Sequence Length Distribution
        34
        0
        0

        All samples have sequences of a single length (101bp).

        Sequence Duplication Levels
        18
        7
        9

        The relative level of duplication found for every sequence.

        From the FastQC Help:

        In a diverse library most sequences will occur only once in the final set. A low level of duplication may indicate a very high level of coverage of the target sequence, but a high level of duplication is more likely to indicate some kind of enrichment bias (eg PCR over amplification). This graph shows the degree of duplication for every sequence in a library: the relative number of sequences with different degrees of duplication.

        Only sequences which first appear in the first 100,000 sequences in each file are analysed. This should be enough to get a good impression for the duplication levels in the whole file. Each sequence is tracked to the end of the file to give a representative count of the overall duplication level.

        The duplication detection requires an exact sequence match over the whole length of the sequence. Any reads over 75bp in length are truncated to 50bp for this analysis.

        In a properly diverse library most sequences should fall into the far left of the plot in both the red and blue lines. A general level of enrichment, indicating broad oversequencing in the library will tend to flatten the lines, lowering the low end and generally raising other categories. More specific enrichments of subsets, or the presence of low complexity contaminants will tend to produce spikes towards the right of the plot.

        Created with Highcharts 5.0.6Sequence Duplication Level% of LibraryChart context menuExport PlotFastQC: Sequence Duplication Levels123456789>10>50>100>500>1k>5k>10k+0%20%40%60%80%100%Created with MultiQC

        Overrepresented sequences
        32
        1
        1

        The total amount of overrepresented sequences found in each library.

        FastQC calculates and lists overrepresented sequences in FastQ files. It would not be possible to show this for all samples in a MultiQC report, so instead this plot shows the number of sequences categorized as over represented.

        Sometimes, a single sequence may account for a large number of reads in a dataset. To show this, the bars are split into two: the first shows the overrepresented reads that come from the single most common sequence. The second shows the total count from all remaining overrepresented sequences.

        From the FastQC Help:

        A normal high-throughput library will contain a diverse set of sequences, with no individual sequence making up a tiny fraction of the whole. Finding that a single sequence is very overrepresented in the set either means that it is highly biologically significant, or indicates that the library is contaminated, or not as diverse as you expected.

        FastQC lists all of the sequences which make up more than 0.1% of the total. To conserve memory only sequences which appear in the first 100,000 sequences are tracked to the end of the file. It is therefore possible that a sequence which is overrepresented but doesn't appear at the start of the file for some reason could be missed by this module.

        Created with Highcharts 5.0.6Percentage of Total SequencesChart context menuExport PlotFastQC: Overrepresented sequencesTop over-represented sequenceH5MVLDMXY_n01_BG0061H5MVLDMXY_n01_BG0063H5MVLDMXY_n01_NR0057H5MVLDMXY_n01_NR0154H5MVLDMXY_n01_Pf3D7H5MVLDMXY_n01_RN0069H5MVLDMXY_n01_mook198_2H5MVLDMXY_n01_sidu032_3H5MVLDMXY_n01_undeterminedH5MVLDMXY_n02_BG0062H5MVLDMXY_n02_BG0067H5MVLDMXY_n02_NR0057.1H5MVLDMXY_n02_NR0154.1H5MVLDMXY_n02_RN0068H5MVLDMXY_n02_RN0072H5MVLDMXY_n02_sidu001_4H5MVLDMXY_n02_sidu036_10%2%4%6%8%10%12%14%16%18%20%22%Created with MultiQC

        Adapter Content
        34
        0
        0

        The cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position.

        Note that only samples with ≥ 0.1% adapter contamination are shown.

        There may be several lines per sample, as one is shown for each adapter detected in the file.

        From the FastQC Help:

        The plot shows a cumulative percentage count of the proportion of your library which has seen each of the adapter sequences at each position. Once a sequence has been seen in a read it is counted as being present right through to the end of the read so the percentages you see will only increase as the read length goes on.

        Created with Highcharts 5.0.6Position (bp)% of SequencesChart context menuExport PlotFastQC: Adapter Content1020304050607080900123456Created with MultiQC

        Status Checks

        Status for each FastQC section showing whether results seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        FastQC assigns a status for each section of the report. These give a quick evaluation of whether the results of the analysis seem entirely normal (green), slightly abnormal (orange) or very unusual (red).

        It is important to stress that although the analysis results appear to give a pass/fail result, these evaluations must be taken in the context of what you expect from your library. A 'normal' sample as far as FastQC is concerned is random and diverse. Some experiments may be expected to produce libraries which are biased in particular ways. You should treat the summary evaluations therefore as pointers to where you should concentrate your attention and understand why your library may not look random and diverse.

        Specific guidance on how to interpret the output of each module can be found in the relevant report section, or in the FastQC help.

        In this heatmap, we summarise all of these into a single heatmap for a quick overview. Note that not all FastQC sections have plots in MultiQC reports, but all status checks are shown in this heatmap.

        Created with Highcharts 5.0.600.250.50.751Section NameChart context menuExport PlotFastQC: Status ChecksBasic St…Basic StatisticsPer Base Sequence QuPer Tile Sequence QuPer Sequence QualityPer Base Sequence CoPer Sequence GC ContPer Base N ContentSequence Length DistSequence DuplicationOverrepresented SequAdapter ContentH5MVLDMXY_n01_BG0061H5MVLDMXY_n01_BG0063H5MVLDMXY_n01_NR0057H5MVLDMXY_n01_NR0154H5MVLDMXY_n01_Pf3D7H5MVLDMXY_n01_RN0069H5MVLDMXY_n01_mook19H5MVLDMXY_n01_sidu03H5MVLDMXY_n01_undeteH5MVLDMXY_n02_BG0062H5MVLDMXY_n02_BG0067H5MVLDMXY_n02_NR0057H5MVLDMXY_n02_NR0154H5MVLDMXY_n02_RN0068H5MVLDMXY_n02_RN0072H5MVLDMXY_n02_sidu00H5MVLDMXY_n02_sidu03Created with MultiQC